Silicon Labs /SiM3_NRND /SIM3U166_B /EXTVREG_0 /CONFIG

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CONFIG

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0_UA)IMINFINE 0 (1_UA)IMIN0 (0_V)FBVOSEL 0 (4_UA_PER_V)FBRATE 0 (2_UA)IMAX0VOUTSEL

IMAX=2_UA, FBVOSEL=0_V, IMIN=1_UA, FBRATE=4_UA_PER_V, IMINFINE=0_UA

Description

Module Configuration

Fields

IMINFINE

Minimum Current Fine Select.

0 (0_UA): Minimum current limit is IMIN current + 0 uA.

1 (0P25_UA): Minimum current limit is IMIN current + 0.25 uA.

2 (0P5_UA): Minimum current limit is IMIN current + 0.50 uA.

3 (0P75_UA): Minimum current limit is IMIN current + 0.75 uA.

IMIN

Minimum Current Select.

0 (1_UA): Minimum current limit is 1 uA + IMINFINE current.

1 (2_UA): Minimum current limit is 2 uA + IMINFINE current.

2 (3_UA): Minimum current limit is 3 uA + IMINFINE current.

3 (4_UA): Minimum current limit is 4 uA + IMINFINE current.

4 (5_UA): Minimum current limit is 5 uA + IMINFINE current.

5 (6_UA): Minimum current limit is 6 uA + IMINFINE current.

6 (7_UA): Minimum current limit is 7 uA + IMINFINE current.

7 (8_UA): Minimum current limit is 8 uA + IMINFINE current.

FBVOSEL

Foldback Voltage Offset Select.

0 (0_V): Foldback voltage offset is 0 V.

1 (0P5_V): Foldback voltage offset is 0.5 V.

2 (1_V): Foldback voltage offset is 1 V.

3 (1P5_V): Foldback voltage offset is 1.5 V.

4 (2_V): Foldback voltage offset is 2 V.

5 (2P5_V): Foldback voltage offset is 2.5 V.

6 (3_V): Foldback voltage offset is 3 V.

7 (3P5_V): Foldback voltage offset is 3.5 V.

FBRATE

Voltage Sense Gain Multiplier.

0 (4_UA_PER_V): Set the foldback rate to 4 uA/V.

1 (2_UA_PER_V): Set the foldback rate to 2 uA/V.

2 (1_UA_PER_V): Set the foldback rate to 1 uA/V.

3 (0P5_UA_PER_V): Set the foldback rate to 0.5 uA/V.

5 (8_UA_PER_V): Set the foldback rate to 8 uA/V.

6 (16_UA_PER_V): Set the foldback rate to 16 uA/V.

7 (32_UA_PER_V): Set the foldback rate to 32 uA/V.

IMAX

Maximum Current Select.

0 (2_UA): Maximum current limit is 2 uA.

1 (3_UA): Maximum current limit is 3 uA.

2 (4_UA): Maximum current limit is 4 uA.

3 (5_UA): Maximum current limit is 5 uA.

4 (6_UA): Maximum current limit is 6 uA.

5 (7_UA): Maximum current limit is 7 uA.

6 (8_UA): Maximum current limit is 8 uA.

7 (9_UA): Maximum current limit is 9 uA.

VOUTSEL

Regulator Output Voltage Select.

Links

()